1. Product Introduction of Rack Mount Ups 1-3kva
The HR series(Rack Mount Ups 1-3kva) is high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage/low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power for load. We adopt standard 2U rack structure.
Double conversion online design
Adopt DSP digital control
With LCD+LED real-time display
Ultra-wide input voltage range
HR single phase pure sinewave online rackmount ups 1000va provides Rack/Tower form factor to fit diverse environment. Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
HR single phase pure sinewave online rackmount ups 1000va for 19″ server racks are compact and fit into 600-mm deep racks. UPS autonomy times can be increased with additional plug & play battery packs and will be automatically detected. Our advanced battery charging technology enables short charging times and battery-preserving charging characteristics simultaneously.
2. Product Parameter (Specification) of Rack Mount Ups 1-3kva
Model | HR1KL | HR2KL | HR3KL | |
Rating | 1kVA/900W | 2kVA/1800W | 3kVA/2700W | |
Input | Input System | L+N+PE | ||
Rated Voltage | 208/220/230/240VAC | |||
Voltage Range |
1. 176Vac~288Vac, full load 2. 120Vac~176Vac, linear derating 3. 120Vac, half load |
|||
Frequency | 50/60+HZ (default), ±10HZ (can be set) | |||
Power Factor | 0.98(conditions:rated voltage, full pure resistive load, fully charged battery | |||
Output | Output System | L+N+PE | ||
Power Factor | 0.8/0.9 | |||
Voltage | 208/220/230/240VAC | |||
Wave Form | Pure Sine Wave | |||
Voltage Harmonic Distortion (Rated Input Voltage. Rated Input Frequency) |
≤3% (0~100% linear load) ≤5% (0~100% non-linear load) |
|||
Frequency | 50 HZ/60 HZ ±0.05% HZ (Battery Model) | |||
Inverter Overload Capability(in normal mode, 25℃) |
>105% 1mins >150% 200mS |
|||
Crest Factor | 3:1 | |||
Transfer Time |
AC Mode Switch To Battery Mode: 0ms Mains Inverter Mode Switch To Bypass Mode: 4ms |
|||
Battery Volatge | 36VDC | 96VDC | ||
Charge Current | 6A | |||
Interface | RS-232 | Support: Windwos 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC | ||
Intelligent Slot(Optional) | SNMP/AS400 Relay Card/RS485 | |||
Environmental Parameters | Operating Ambient Temperature | 0~40℃ | ||
Operating Environment Humidity | 20%~95% (No Condensation) | |||
Storage Temperature | -15~60℃ (Battery:0~40℃) | |||
Altitude | The Altitude Should Not Exceed 1000m, Derating Above1000m, Up To 4000m (max), Refer IEC62040 | |||
Noise | ≤45db | |||
Dimensions (D*W*H) (mm) | 437*468*88mm(2U) | |||
Net weight (kg) | 7.8 | 9.6 | 10 |
3. Product Feature and Benefits of Rack Mount Ups 1-3kva
1). True double-conversion online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
2). Innovative security
An innovative locking mechanism at the UPS outputs’ prevent accidental separation of the loads.
3). Wide input voltage range (120V-300V)
HR series UPS can still provide stable power to connected devices under unstable power environments.
4). Communication
Many interfaces (RS232 / USB / Slot / EPO) as well as a potential-free contact within the series ensure an outstanding communication capacity. A real-time event logger ensures careful observation and analysis of events as they occur.
5). LCD + LED status display
The multilingual graphic screen is very easy to read, even from a longer distance, thanks to its large format.
6). Compact design
The height of the UPS electronics and battery together is only 2 U. With the flap front cover, battery replacement is very easy. The autonomy times can be increased with additional battery packs; connected battery packs are automatically detected.
Rear
7). Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
8). Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
9). Battery management
All batteries can be replaced during operation (hot-swappable).
10). Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
11). Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
12). Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
13). Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
4. FAQ
1)If OEM is acceptable?
Yes, we can provide the OEM service for Logo printing on UPS, Custom manual etc.
2) How to proceed with an order?
A. Firstly let us know your requirements or application. Secondly, We quote according to your requirements or our suggestions. Thirdly, customer confirms the samples and places a deposit for formal order. Fourthly, We arrange the production.
3) Can I delivery the goods from other supplier to your factory?
Then load together? Sure, that's no problem.
4) Are you a trading company or a manufacturer?
A professional manufacturer and developer of UPS.
5) How is your after-sale service?
We provide 12-24 months warranty since the delivery date and free maintenance/replacement during warranty period.
6) Do you have any MOQ?
Yes, we have MOQ for mass production, it depends on the different part numbers. 1~10pcs sample order is available. Low MOQ, 1pc for sample checking is available.
7) Can I have a sample order?
Yes, we welcome sample order to test and check quality.
8) What kind of material of transformer?
We have two types, one 100% copper and the other is copper with aluminum. It depends on your requirement. In fact, those two have no difference if normal work well. Only except the long life. Copper is better and also higher price.